Perseus
Level and water ingress sensors
Sensors that notice when liquid reaches them. The capacitive models detect liquid in ballast tanks and water coming into a space; the float model opens a contact when water lifts its float.
Specifications
- Principle
- 4000-V2, 5000, 5000-C: capacitive, the probe's capacitance changes when liquid reaches it. 2000: float with a hermetically sealed reed switch, normally closed, opening on alarm
- Supply
- 4000-V2: 9 to 13 V DC. 5000, 5000-C: 8 V DC
- Output
- 4000-V2: 5.5 mA with the LED on, 2.5 mA with the LED off. 5000, 5000-C: alarm trigger
- Sensitivity, 4000-V2
- adjustable; finest practical setting 0.5 pF
- Media temperature
- 4000-V2: −50 to +100 °C (amplifier −5 to +60 °C). 5000, 5000-C: 0 to +80 °C
- Maximum probe pressure, 4000-V2
- 200 bar
- Process connection
- 4000-V2: G ¾". 5000: G ¼". 5000-C: 1" taper thread (BSPT)
- Electrical connection
- 4000-V2: terminal block, for cable 5 to 10 mm. 5000, 5000-C: cable terminals, PVC cable
- Materials
- probe and housing AISI 316L; electrode insulation POM (acetal); enclosure of the 4000-V2 aluminium alloy
- Protection class
- IP68; enclosure of the 4000-V2: IP66
- Installation position
- any
- Perseus 2000
- G 2½"; housing and push-fit adaptor POM (acetal); PVC cable 2 × 1 mm², 30 m, longer on request; −20 to +80 °C; IP68
The models
-

Perseus 2000
Float-type water ingress detector with a sealed reed switch; POM housing, G 2½", 30 m of cable
-

Perseus 4000-V2
Level sensor for ballast tanks; aluminium enclosure, G ¾"
-

Perseus 5000
Water ingress sensor, G ¼"
-

Perseus 5000-C
Water ingress sensor, 1" taper thread, cable to length
Where it works
- Ballast tanks
- Water ingress detection
- Cargo holds and forward spaces
Options and versions
- Sensitivity set for the medium (4000-V2)
- Cable to length (5000-C)