Hermes
Pressure transmitters
Pressure transmitters with a ceramic sensor in an AISI 316L stainless steel housing, for gases, vapours and liquids up to 50 bar. Each one is calibrated to the range you ask for, and its calibration report is in the box.
See inside a Hermes 3000 Ask about Hermes
Move the pointer over the steel to look inside.
From pressure to 4–20 mA, in ten parts.
Keep scrolling. The Hermes 3000 comes apart in the order the signal travels: in through the thread, out through the connector.
-
1
Thread connection
Threads into the line and carries the medium to the sensor. AISI 316L stainless steel, with the thread made to order: ¼", ⅜", ½", ¾", 1" or M20×1.5.
-
2
O-ring
Seals the sensor cell against the process medium.
-
3
Sensor cell
A ceramic cell. It flexes under pressure and turns that movement into a small electrical signal.
-
4
Retaining ring
Holds the sensor cell seated on its seal.
-
5
Electronics
Conditions the sensor signal into a two-wire 4–20 mA loop, protected against reverse polarity, EMI and ESD.
-
6
Housing
A stainless steel sleeve that closes the instrument around the electronics.
-
7
Terminal insert
Brings the loop out of the housing on blade terminals.
-
8
Locking nut
Clamps the terminal insert to the housing.
-
9
Gasket
Seals the face between insert and connector.
-
10
Connector
DIN plug with cable gland. Two wires: supply in on one, 4–20 mA back on the other.
Specifications
- Measuring range, gauge
- up to 50 bar (smallest span 0.25 bar)
- Measuring range, absolute
- up to 50 bar (smallest span 1 bar)
- Vacuum
- down to −1 bar, depending on the span
- Accuracy
- ±0.05 % FS
- Thermal offset shift
- ±80 μA FS, 25 to 85 °C
- Output
- two-wire 4–20 mA current loop
- Supply
- 11 to 30 V DC, protected against reverse voltage
- Media temperature
- −40 to +135 °C
- Storage temperature
- −20 to +110 °C
- Process connection
- G ¼", ⅜", ½", ¾", 1", M20×1.5 EN 837, flange, or to your drawing
- Electrical connection
- DIN EN 175301-803-A connector (3000, 6000); terminal block (7000); KK 254 connector or cable (7100)
- Housing
- AISI 316L stainless steel
- Sensor diaphragm
- ceramic, Al₂O₃ 96 %
- Protection class
- IP65 (3000, 6000); IP68 (7000, and 7100 with its cable fitted)
- Burst pressure and overload
- 3 to 5 × and 2 to 3 × the range
- Hermes 3000 size
- 138 mm long, Ø 28 mm, 53 mm across the connector
- Documents
- calibration report with every instrument
Ten parts, in the order the signal travels.
The models
-

Hermes 3000
Thread connection, DIN connector, IP65
-

Hermes 6000
G ⅛" or ¼" female, or flange; DIN connector
-


Hermes 7000
Aluminium junction box with terminal block; thread or flange (DIN, JIS); IP68
-

Hermes 7100
Compact, G ½"; KK 254 connector, cable optional; IP68 with the cable fitted
Where it works
- Marine and offshore
- Pneumatics and hydraulics
- Process industry
- Pumps and compressors
- HVAC
- Environmental engineering
Options and versions
- Gauge or absolute reference
- Calibrated to the span you ask for
- Thread, flange or custom process connection
- Cable to length on the 7100